TM 55-1520-240-23-6
7-86
INSTALL EXTENSIBLE LINK
(Continued)
7-86
2.
On removed extensible link (5), remove authority
cover (6) as follows:
a.
Remove lockwire from four screws (7).
Cover is spring-loaded. Remove with
caution, otherwise personnel injury
can occur.
b.
Apply hand pressure to cover (6). Remove
four screws (7) from cover.
c.
Remove and tag data plate (8) and authority
cover (6). Remove and discard packing (8.1).
d.
Erase or cover over -5 thru -11 dash number
and axis identification, and stamp -8 or -12
on data plate (8).
3.
On replacement extensible link (1), install
authority cover (6) as follows:
NOTE
Make sure data plate is marked
with correct dash number and
corresponding axis identification as
shown in table A.
a.
Remove tag from data plate (4). Position new
packing (8.1), authority cover (6), and data
plate on link (1).
b.
Install four screws (7). Torque to 30
inch-pounds.
c.
Lockwire screws (7). Use lockwire (E231).
7-352