TM 55-1520-240-23-6
7-83.1
INSPECT INTEGRATED LOWER CONTROL ACTUATOR (ILCA)
(Continued)
7-83.1
11.
Check for axial looseness between lever (16)
and bearings (17 and 18). Preload dial indicator
(6) against lever. Push and hold bolt (19). Move
lever toward, then away from, indicator. Record
indicator reading. Reading shall not be greater
than 0.0040 inch.
7-335