TM 55-1520-240-23-6
7-54.1
REMOVE NO. 1 OR NO. 2 POWER CONTROL MODULE MISCELLANEOUS CHECK
VALVES
(Continued)
7-54.1
6.
Spread puller halves (2), by retracting sleeve (3)
until pin (4) bottoms in groove (5).
7.
Holding puller halves (2) apart, place tool over
check valve (6). Release puller halves and locate
tool over groove of lockring (1). Slide sleeve
(3) over puller halves to close tool on lockring
groove. Check for proper engagement with
lockring groove.
NOTE
Be sure to pull out lockring (1) straight,
and only enough to clear lockring
serrations.
8.
Turn bolt (7) clockwise while holding sleeve (3).
This will jack the lockring (1) out of port (8). Stop
turning bolt (7) when the external serrations of
lockring (1) clear the port.
9.
Loosen bolt (7), lift sleeve (3), and free puller
halves (2). Remove tool from check valve (6).
7-265