TM 55-1520-240-23-6
7-49.1
ASSEMBLE ACCUMULATOR (AD-A620-1D340)(AVIM)
(Continued)
7-49.1
7.
Place gas port end of housing (1) in vise (10).
8.
Apply light coat of hydraulic fluid (E199) in
retainer area of packing (6). Use cloth (E120).
9.
Thread retainer (3) into housing (1) and torque to
30 to 40 foot-pounds.
10.
Install spiral retaining ring (11) into retaining ring
groove of housing (1).
11.
Apply light coat of hydraulic fluid (E199) to
packing (12) and retainer rings (13).
12.
Install packing (12) and retainer rings (13) on
port end of retainer (3).
13.
Remove accumulator (1) from vise (10).
FOLLOW-ON MAINTENANCE:
Test accumulator (Task 7-50).
END OF TASK
7-245