TM 55-1520-240-23-6
7-40.1
REMOVE NO. 1 OR NO. 2 POWER CONTROL MODULE HIGH PRESSURE CHECK
VALVE
(Continued)
7-40.1
NOTE
Deplete pressure in system by cycling
cockpit control stick (Task 1-64).
1.
Disconnect connector (1) from switch (2).
2.
Remove two screws (3) from switch (2).
3.
Remove lockwire from bowl (4). Remove bowl
from module (5). Use cloths (E135) for spilled
fluid. Wear gloves (E184.1). Use strap wrench.
7-205