TM 55-1520-240-23-6
7-28
INSTALL NO.2 FLIGHT CONTROL HYDRAULIC PUMP
(Continued)
7-28
2.
Install packing (1) and union (2) in IN port (3).
3.
Install packing (4) and elbow (6) in OUT port (7).
Tighten nut (8).
4.
Install packing (9) and elbow (11) in SD port (12).
Tighten nut (13).
5.
Install packing (14) and union (15) in case drain
port (15.1).
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
Do not install pump with dry case.
This can cause internal damage to
pump.
6.
Fill pump case (16) through case drain port (17).
Use hydraulic fluid (E199). Use cloths (E120) for
spilled fluid. Wear gloves (E184.1).
7-171