TM 55-1520-240-23-6
7-337
BLEED UTILITY HYDRAULIC CENTER CARGO HOOK SYSTEM
7-337
INITIAL SETUP
Applicable Configurations:
All
Tools:
Hydraulic Repairers Tool Kit, NSN 5180-00-323-4891
Container, 2 Quart
Materials:
Cloths (E120)
Gloves (E186)
Personnel Required:
Aircraft Pneudraulics Repairer (2)
Equipment Condition:
Battery Connected (Task 1-39)
Electrical Power On
Hydraulic Power On
Cargo Hook Actuator Serviced (Task 1-74)
Hydraulic Test Stand Connected to Ground Service
Panel (Task 1-38)
Rescue Hatch Open (Task 2-2)
General Safety Instructions:
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
Hydraulic fluid ejected under pressure
can cause injury to personnel.
Hydraulic fluid sprayed into the air is
a fire hazard.
7-1241