TM 55-1520-240-23-6
7-322
FLUSH WHEEL BRAKE PRESSURE TUBING
(Continued)
7-322
Filter assembly kit
ADHT6814-M9716M must be
installed in test stand pressure
line. Otherwise, system can be
contaminated.
NOTE
To operate hydraulic test stand, refer
to applicable manual.
1.
Working from ramp, disconnect tube (1) from
BK STRG PRESS port (2) of pressure control
module (3).
2.
Connect test stand pressure hose (4) to tube (1).
3.
Disconnect tube (5) from IN port (6) of pressure
reducer (7).
4.
Disconnect tube (8) from OUT port (9) of reducer
(7).
5.
Connect hose (10) to tube (5) and tube (8).
6.
Disconnect tube (11) from IN PRESS port (12) of
power steering/swivel lock module (13).
7.
Install plug (14) in tube (11).
7-1166