TM 55-1520-240-23-6
7-318
FLUSH NO. 1 AND NO. 2 PTU AND CARGO HOOK RETURN TUBING
(Continued)
7-318
Filter assembly Kit
ADHT6814-M9716M must be
installed in test stand pressure line.
NOTE
To operate hydraulic test stand refer
to applicable manual.
1.
Working from ramp, disconnect PTU RTN tube
(1) from control module (2).
2.
Connect test stand pressure hose (3) to tube (1).
3.
Working from aft left pylon disconnect tube (4)
from PTU RTN port (5).
4.
Install plug (6) in tube (4).
7-1142