TM 55-1520-240-23-6
7-317
FLUSH NO. 1 AND NO. 2 PTU AND CARGO HOOK PRESSURE TUBING
(Continued)
7-317
Filter assembly kit
ADHT6814-M9716M must be
installed in test stand pressure line.
NOTE
To operate hydraulic test stand, refer
to applicable manual.
1.
Working from ramp, disconnect PTU PRESS
tube (1) from control module (2). Use gloves
(E186).
2.
Connect test stand pressure hose (3) to tube (1).
3.
Working from aft left pylon, disconnect tube (4)
from PTU PRESS port (5).
4.
Install plug (6) in tube (4).
5.
Working from center tunnel, disconnect two
tubes (7 and 8) from hook release valve (9).
6.
Connect hose (10) to tube (7).
7.
Connect hose (10) to tube (8).
7-1136