TM 55-1520-240-23-6
7-270
INSTALL RAMP CONTROL VALVE
(Continued)
7-270
NOTE
Tubing shown under valve without
65 same tubing to be connected to
valve with 65 . For ease of display,
call-outs have been left off tubing
under valve with 65 .
4.
Connect seven hydraulic tubes (10). Remove
tags.
5.
Tighten bolts (9).
6.
Tighten two nuts (11).
7.
On valve with 65 , install connector (12).
INSPECT
FOLLOW-ON MAINTENANCE:
Bleed cargo ramp hydraulic system (Task 7-339).
Perform operational check of ramp control valve (TM
55-1520-240-T).
END OF TASK
7-1011