REPLACE  COMBINING  TRANSMISSION  SIGHT  GAGE
REPLACE  COMBINING TRANSMISSION SIGHT GAGE (Continued)

TM-55-1520-240-23-5 CH-47D Heilcopter Manual
Page Navigation
  625    626    627    628    629  630  631    632    633    634    635  
TM  55-1520-240-23-5 6-193 REPLACE  COMBINING TRANSMISSION  SIGHT GAGE (Continued) 6-193 REMOVE  SIGHT GAGE 1. From  inside  cabin, connect  hose  to  drain  valve (1).  Direct  end  of  hose  into  container. 2. Have  helper  view  sight  gage  (2)  on  sump  (3). Push  in  drain  valve  (1),  twist  and  pull.  Drain  oil until  level  is below  gage. 3. Close  drain  valve  (1)  by pushing  it  in  and  twisting it.   Disconnect  hose  from  valve. 4. Remove  lockwire  from  sight  gage  (2).   Remove gage  from  sump  (3).  Use  spanner  wrench. 5. Remove  packing  (4)  from  sight  gage  (2). INSTALL SIGHT GAGE Oil  (E254)  is  toxic.  It can  irritate  skin and  cause  burns.  Avoid  inhaling.  Use only with  adequate  ventilation.  Avoid contact  with  skin,  eyes,  or  clothing. In  case  of contact,  immediately  flush skin  or  eyes  for  at least 15 minutes. Get medical  attention  for  eyes. 6. Coat  packing  (4)  and  thread  of  sight  gage  (2) with  oil  (E254).  Install  packing  on  gage. 7. Install  sight gage  (2)  in  sump  (3).   Use  spanner wrench.  Torque  gage  to  80 inch-pounds. 6-639