ASSEMBLE  COMBINING  TRANSMISSION  SUMP
ASSEMBLE  COMBINING TRANSMISSION  SUMP (Continued)

TM-55-1520-240-23-5 CH-47D Heilcopter Manual
Page Navigation
  618    619    620    621    622  623  624    625    626    627    628  
TM  55-1520-240-23-5 6-191 ASSEMBLE  COMBINING TRANSMISSION SUMP (Continued) 6-191 4. Lockwire  sight  gage  (7)  at  front  of  sump  (3)  to temperature  probe  (3).  Lockwire  two  sight  gages (8)  at  sides of  sump  to  drain  valves  (6).   Use lockwire  (E231). 5. Lockwire  two  temperature  probes (2)  at sides of sump  (3)  to  sump.  Use  lockwire  (E231). 6. Install  three  screens (9)  and  retaining  rings  (10). INSPECT ASSEMBLE  SUMP  COVER Dry  cleaning  solvent  (E162)  is flammable  and  toxic.   It  can  irritate skin  and  cause  burns.   Use  only  in well-ventilated  area, away from  heat and  open  flame.   In  case  of  contact, immediately  flush  skin  or  eyes  with water  for  at  least  15 minutes.   Get medical  attention  for  eyes. 7. Clean  inside  of  filter  housing  (11)  with  dry cleaning  solvent (E162)  and  clean  cloths (E120). Check  that  hole  (12)  is  free  of  debris.   Wear gloves (E186). 8. Hold  housing  (11)  so  that  indicating  button  (13) points straight  up.  Push  in  button  to  lock it  down. 9. Install  element (14)  in  housing  (11). 10. Install  gasket  seal  (15),  and  housing  (11)  on  four studs  (16).   Install  four  washers  (17)  and  nuts (18).  Torque  nuts  to  60 inch-pounds. 6-632