TM  55-1520-240-23-5 6-113.1 REPAIR FORWARD  TRANSMISSION  OIL COOLER  OUTSIDE  SURFACE 6-113.1 INITIAL  SETUP Applicable  Configurations: All Tools: Dial  Indicating  Depth  Gage  643J Goggles Fluorescent  Penetrant Method Materials: Naphtha  (E245) Emery  Cloth  (E13)  or Abrasive  Paper  (E13) Crocus  Cloth  (E122) Cloths  (E120) Gauze  Sponges  (E184) Gloves  (E186) Acetic  Acid  (E21) Alodine  Powder  (E65) Epoxy Primer  (E293) Epoxy Topcoat  (E166) Personnel  Required: Aircraft  Powertrain  Repairer Inspector References: TM  1-1500-335-23 Equipment  Condition: Off  Helicopter  Task General Safety Instructions: Naphtha  (E245)  is  combustible  and toxic.   It can  irritate  skin  and  cause burns.   Use  only  with  adequate ventilation, away from  open  flame.  In case  of  contact,  immediately  flush skin  or  eyes  with  water  for  at  least 15  minutes.   Got medical  attention for  eyes. Acetic acid  (E21)  is  combustible  and toxic.   It can  irritate  skin  and  cause burns.   Avoid  inhaling.  Use  only with adequate  ventilation,  away  from open  flame.  Avoid  contact  with  skin, eyes,  or  clothing.  In  case  of contact, immediately  flush  skin  or  eyes  with water  for  at  least 15 minutes.   Get medical  attention  for  eyes. Alodine  powder  (E65)  is  an  oxidizer. Discard  cloths  which  contain  this material  in  a  separate  container.   If discarded  with  cloths contaminated with  acetone,  MEK,  or  other  organic solvents,  combustion  can  result.   In case  of  contact,  immediately  flush skin  or  eyes  with  water  for  at  least 15  minutes.   Get medical  attention for  eyes. Epoxy  primer  (E293)  is  flammable and  toxic.   It  can  irritate  skin  and cause  burns.  Use  only with  adequate ventilation,  away  from  heat  or  open flame.   Avoid  contact  with  skin,  eyes, or  clothing.    In  case  of  contact, immediately  flush  skin  or  eyes  with water  for  at  least 15 minutes.   Get medical  attention  for  eyes. Do  not wear  photogray glasses when fluorescent  inspecting.   They  reduce ability  to  see  cracks. 6-440







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.