TM  55-1520-240-23-5 6-43 INSTALL FORWARD  TRANSMISSION INPUT SHAFT SEAL 6-43 INITIAL  SETUP Applicable Configurations: All Tools: Aircraft  Mechanic’s Tool  Kit, NSN 5180-00-323-4692 Aluminum  Tube,  4-1/4  Inch  OD,  1/8  Inch  Wall Thickness,  1  to  6  Inches Long Gun  Heater Pyrometer Torque  Wrench,  30  to  150  Inch-Pounds Materials: Gloves  (E186) Dry  Cleaning  Solvent  (E162) Cloths  (E120) Kevlar  Gloves  (E187) Parts: Packings Personnel  Required: Medium  Helicopter Repairer Inspector References: TM  55-1520-240-23P General Safety Instructions: Dry  cleaning  solvent  (E162)  is flammable  and  toxic.   It  can  irritate skin  and  cause  burns.   Use  only  in well-ventilated  area, away  from  heat and  open  flame.   In  case  of contact, immediately flush  skin  or eyes  with water  for  at  least 15 minutes.   Get medical  attention  for eyes. 6-141