REMOVE  PITCH HOUSING OIL TANK SIGHT INDICATOR (Continued)
REMOVE  VERTICAL HINGE  PIN OIL TANK SIGHT INDICATOR

TM-55-1520-240-23-4 CH-47D Heilcopter Manual
Page Navigation
  74    75    76    77    78  79  80    81    82    83    84  
TM  55-1520-240-23-4 5-13 INSTALL PITCH  HOUSING OIL TANK  SIGHT INDICATOR 5-13 INITIAL  SETUP Applicable Configurations: All Tools: Aircraft  Mechanic’s Tool  Kit, NSN 5180-00-323-4692 Torque  Wrench,  30  to  150  Inch-Pounds Materials: Lubricating  Oil  (E254/E254.1) Parts: Packing Personnel  Required: Medium  Helicopter Repairer Inspector References: TM  55-1520-240-23P General Safety Instructions: Oil  (E254/E254.1)  is  toxic.   It  can irritate  skin  and  cause  burns.   Avoid inhaling.   Use  only  with  adequate ventilation.  Avoid  contact  with  skin, eyes,  or clothing.  In  case  of contact, immediately flush  skin  or  eyes  for at  least  15  minutes.   Get  medical attention  for  eyes. NOTE Procedures are  same  for installing  any pitch  housing  oil tank sight indicator. 1. Lubricate  packing  (1).   Use  lubricating  oil (E254/E254.1).   Install  packing  (1),  on  sight indicator  (2). 2. Install  indicator  (2)  in  pitch  housing  oil  tank (3). Torque  indicator  to  115 inch-pounds.   Do  not lockwire  at  this  time. INSPECT FOLLOW-ON MAINTENANCE: Service  pitch  housing  oil  tank (Task  1-56). END  OF  TASK 5-81