TM 55-1520-240-23-4
5-123.1
INSPECT AND REPAIR BALL SPHERICAL BEARING
(Continued)
5-123.1
8.
Fluorescent inspect reworked area to check for
cracks (TM 1-1500-335-23). There shall be no
cracks. If a crack in the ball spherical bearing is
suspected, refer to TM 1-1520-253-23.
9.
Apply surface treatment to reworked area as
follows:
a.
Clean area with naphtha (E245) and clean
cloths (E120). Let area air dry. Wear gloves
(E186).
Alodine powder (E65) is an oxidizer.
Discard cloths which contain this
material in a separate container. If
discarded with cloths contaminated
with acetone, MEK, or other organic
solvents, combustion can result. In
case of contact, immediately flush
skin or eyes with water for at least
15 minutes. Get medical attention
for eyes.
b.
Swab solution of alodine powder (E65) in
water on area. Swab for 2 to 5 minutes. Use
gauze sponges (E184). Wear gloves (E186).
c.
Rinse area with cold water. Let air dry.
INSPECT
FOLLOW-ON MAINTENANCE:
None
END OF TASK
5-681