TM  55-1520-240-23-4 5-82.1 ADJUST BLADE  BALANCE  WEIGHTS (Continued) 5-82.1 Weights  and  spacers  must  be removed  from  one  tube  at  a  time. Each  weight  and  spacer  should  be marked  to  identify  the  tube  it  came from.  Keep  weights  from  each  tube separated.  Improper  adjustment  can make  blade  tracking  impossible. d. Remove  tracking  spacers  (6),  tracking weights  (7),  span  balance  weights  (8)  and wooden  spacer (9) from  tube.  Keep  weights and  spacers from  each  tube  separated. NOTE A  stiff  wire,  bent  90º  at  the  end  to form  a  hook,  can  be  used  to  remove spacers  and  weights. 5-505