TM  55-1520-240-23-4 5-81.3.1 REPLACE  LIGHTNING PROTECTION  JUMPER STRIP 5-81.3.1 INITIAL  SETUP Applicable  Configurations: All Tools: Airframe  Repairer’s Tool  Kit, NSN  5180-00-323-4876 Heat  Lamp Vacuum  Pump Materials: Abrasive  Paper  (E9) Acetone  (E20) Cloth  (E120) Fiberglass  Laminate  (E168  or  E168.1) Scrim  Cloth  (E325) Adhesive  (E40,  E41, E43  or  E47.1) Polyethylene  Cup  (E157) Wood  Spatula  (E424) Peel  Ply  (E270) Teflon-Impregnated  Fabric  (E170) Rubber  Sheet  (E318) Fiberglass  Cloth  (E130) Masking  Tape  (E388) Sealing  Tape  (E396) Teflon  Tape  (E399) Polyvinyl  Sheet (E284) Temperature  Indicating  Strips (E413) Gloves  (E186) Curing  Agent  (E158.1) NOTE Scrim  cloth  is not  required  if  adhesive (E41)  is  used.    Adhesive  (E41) contains beads  which  prevent it  from being  squeezed  below  the  thickness of  the  beads. Parts: Jumper  Strip  114R1750-12 Doubler  114R1702-24 Personnel  Required: Aircraft  Structural  Repairer Inspector Equipment  Condition: Off  Helicopter  Task 5-478