TM 55-1520-240-23-4
5-66.4
REPAIR ROOT END SLOT SEAL
(Continued)
5-66.4
Sealant (E336) can irritate skin and
cause burns. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
4.
Mix sealant (E336) in accordance with the
manufacturers instructions.
NOTE
Working life of sealant (E336) is about
30 minutes.
5.
Temporarily fit root slot seal (2) in open root slot
(3). Note amount of gap between ends of slot
filler (4) and ends of root slot. Draw outline (5) of
slot seal (2) on blade root. Remove seal (2).
6.
Apply sealant to area within outline (5). Apply
sealant at ends of root end slot (3) to completely
fill gap between slot and end of filler (4).
5-325