  153    154    155    156    157  158  159    160    161    162    163  
TM  55-1520-240-23-4 5-35 INSTALL  VERTICAL HINGE  PIN  INNER SEAL 5-35 INITIAL  SETUP Applicable  Configurations: All Tools: Powertrain  Repairer’s  Tool  Kit,   NSN 5180-00-003-5267 Seal  Puller  (T10) Guide  Plug  Set (T12) Materials: Dry  Cleaning  Solvent  (E162) Adhesive  (E63.1) Cloth  (E120) Grease  (E190) Lubricating  Oil  (E254/E254.1) Gloves  (E186) Personnel  Required: Aircraft  Powertrain  Repairer (2) Inspector References: TM  55-1520-240-23P General  Safety Instructions: Dry  cleaning  solvent  (E162)  is flammable  and  toxic.   It  can  irritate skin  and  cause  burns.   Use  only  on well-ventilated  area, away from  heat and  open  flame.   In  case  of  contact, immediately  flush  skin  or eyes  with water for  at  least  15 minutes.   Get medical attention  for eyes.  Use  gloves (E186). Oil  (E254/E254.1)  is  toxic.   It  can irritate  skin  and  cause  burns.   Avoid inhaling.   Use  only  with  adequate ventilation.  Avoid  contact  with  skin, eyes,  or  clothing.  In  case  of  contact, immediately  flush  skin  or  eyes  for at  least  15  minutes.   Get  medical attention  for eyes. NOTE Procedure  is  similar to  install  vertical hinge  pin  inner  seal  in  any  pitch housing  lug. 1. Remove  preservative  from  seal  (1).  Use  cloth (E120) damp  with  solvent  (E162).  Wear  gloves (E186). 2. Check  seal  lips (2)  for  nicks  or  scratches.  Use magnifier.  There  shall  be  no  nicks  or scratches. 5-160







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.