REMOVE  PITCH  HOUSING  SEALS
REMOVE PITCH HOUSING SEALS (Continued) REMOVE  INBOARD  SEAL

TM-55-1520-240-23-4 CH-47D Heilcopter Manual
Page Navigation
  123    124    125    126    127  128  129    130    131    132    133  
TM  55-1520-240-23-4 5-24 REMOVE  PITCH  HOUSING SEALS (Continued) 5-24 2. Apply thin  coat  of  grease  (E190) to  bearings (1) to  hold  them  in  cage  (2).   Position  bearings  in cage. Seal  Puller  (T8)  utilizes  a  set  of fingers/jaws  P/N  114E5809-3  for seal removal  and  a  set  of  finger/jaws P/N 114E5809-15  for bearing  removal. Ensure  fingers/jaws  P/N  114E5809-3 are  installed  in  puller to  preclude damaging  the  outboard  bearing. REMOVE  OUTBOARD  SEAL 3. Position  seal  puller  (T8) (3) in  housing  (4) deep enough  to  allow fingers (5) to  grasp  seal  (6). 4. Hold  nut  (7) and  turn  shaft  (8) counterclockwise until  fingers  (5)  unseat  seal  (6).  Use  wrench  to prevent  nut  from  turning. 5. Remove  puller  (T8) (3) and  seal  (6). 5-130