TM  55-1520-240-23-3 4-140 INSTALL AND RIG POWER TURBINE CONTROL LINKAGE (Continued) 4-140 17. Lift  switch  guard  (44)  on  panel  (45).   Set  left switch  (46) to  MANUAL. Set EMERG  ENG  TRIM No.  1  switch  (47) to  INCR  for 8  to 10  seconds. NOTE Refer to  Task  4-137  to  install  power turbine  limiting  stop. 18. Check  pointer  (36) on  fuel  control  shaft  (2). Pointer  shall  contact N2  RPM  limiting  stop  (48). 19. Have  helper set switch  (47) to  DECR  for  8 to 10 seconds. 20. Check  pointer  (36).   Pointer shall  contact  MIN stop  (37). 21. Lower switchguard  (44). 4-460