TM 55-1520-240-23-3
4-128
INSTALL REMOTE POSITIONING CONTROL BOX
4-128
INITIAL SETUP
Applicable Configurations:
Without 74
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Materials:
None
Personnel Required:
Medium Helicopter Repairer
Inspector
References:
TM 55-1520-240-23P
NOTE
Procedure is same to install No. 1 or
No. 2 remote positioning control. No.
2 box is shown here.
Two types of boxes are used
(SYLZ7561-3 and SYLZ7561-4).
Procedure is same for both.
1.
Position box (1) on shelf (2).
2.
Install four screws (3) and washers (4).
3.
Connect electrical connector (5).
INSPECT
FOLLOW-ON MAINTENANCE:
Install No. 1 remote positioning control box
access cover (Task 2-2) or close right electrical
compartment access door (Task 2-2).
Perform operational check of power turbine system
(TM 55-1520-240-T).
END OF TASK
4-432