TM 55-1520-240-23-3
3-36
INSPECT AFT LANDING GEAR STATIC GROUND WIRE
3-36
INITIAL SETUP
Applicable Configurations:
All
Tools:
None
Materials:
None
Personnel Required:
Medium Helicopter Repairer
Equipment Condition:
Battery Disconnected (Task 1-39)
Electrical Power Off
Hydraulic Power Off
NOTE
This procedure is for left gear only.
1.
Check bracket (1) and attaching hardware for
cracks and corrosion.
2.
Check wire (2) for fraying and positive ground
contact.
3.
Replace wire which is frayed. Replace wire
which does not contact ground. Check wire (2)
for pitting and burn marks from lightning strike
damage.
FOLLOW-ON MAINTENANCE:
None
END OF TASK
3-90