• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
REMOVE  AIR  DATA  TRANSDUCER
REMOVE  INCLINOMETER  SENSOR

TM-55-1520-240-23-10 UH-1H/V and EH-1H Aircraft Manual
Page Navigation
  744    745    746    747    748  749  750    751    752    753    754  
TM  55-1520-240-23-10 16-93 INSTALL AIR  DATA TRANSDUCER 16-93 Applicable Configurations: All Tools: Aircraft  Mechanic’s Tool  Kit, NSN 5180-00-323-4692 Materials: None Personnel  Required: Medium  Helicopter Repairer Inspector Equipment  Condition: TM  55-1520-240-23P 1. Position  transducer (1)  on  mounting  plate  (2). Install  four  screws  (3)  and  washers (4). 2. Connect  PITOT  PRESS  air  hose  (5).   Remove tag. 3. Connect  STATIC PRESS  air hose  (6).   Remove tag. 4. Connect  electrical connector  (7).  Remove  tag. INSPECT FOLLOW-ON MAINTENANCE: Perform  leak  check  of  pitot-static  system  (TM 55-1520-240-T). END  OF  TASK 16-341