TM 55-1520-240-23-10
15-7
INSTALL APU AFT MOUNT CONNECTING LINKS
(Continued)
15-7
INSTALL APU HORIZONTAL AFT MOUNT
CONNECTING LINK
NOTE
Two bushings are installed in fitting
for link alignment.
5.
Remove nut (9), bolt (10), two washers (11), and
washer (11.1) from fitting (12).
6.
Position link (13) in fitting (12). Install bolt (10),
washer (11.1), two washers (11), and nut (9).
7.
Position link (13) in clevis (14). Install bolt (15),
two washers (16), washer (16.1), and nut (17).
8.
Have helper operate hoist (18) to remove tension
from cable (19).
9.
Remove bolt (20) and nut (21) to disconnect
cable (19) from links (22).
10.
Unhook tackle block (23) from fitting (24).
11.
Remove bolt (25) and nut (26) from lug (27) and
clevis (28). Remove hoist (18).
INSPECT
FOLLOW-ON MAINTENANCE:
Install APU drip pan (Task 2-3).
Close ramp work platform (Task 2-2).
Close cargo ramp (TM 55-1520-240-T).
END OF TASK
15-33