TM 55-1520-240-23-10
15-3
REMOVE AUXILIARY POWER UNIT (APU)
(Continued)
15-3
7.
Remove nut (22), bolt (23), two washers (24),
and washer (24.1). Remove link (25) from clevis
(26).
8.
Loosen clamp (27). Slide exhaust duct (28) aft.
8.1.
Disconnect bonding jumper assembly (28.1).
9.
Open quick-release clamp (29). Disconnect fuel
hose at quick-disconnect fitting (30) on airframe
bulkhead.
10.
Tag and disconnect drain hose (31). Use tags
(E264). Use container and cloths (E135) for
spilled fuel. Plug hose and cap fitting (32).
11.
Tag and disconnect vent hose (33). Use tags
(E264).
12.
Disconnect plug (34).
15-10