TM  55-1520-240-23-10 14-11 INSTALL WINCH WIRE  ROPE  (CABLE) 14-11 INITIAL  SETUP Applicable Configurations: All Tools: Aircraft  Mechanic’s Tool  Kit, NSN  5180-00-323-4692 Container,  Two  Quart Materials: Cloths  (E120) Lockwire  (E229) Gloves,  Wire  Handling  (E185) Personnel  Required: Medium  Helicopter  Repairer  (2) Inspector References: TM  55-1520-240-23P TM  55-1520-240-T General Safety Instructions: Wear  wire  handling  gloves  when installing wire rope (cable).  Otherwise, injury to  hands  can  result. 1. Guide  wire  rope  (1)  through  bracket  (2)  and guard  (3)  until  cable  ball  end  (4)  extends past bulkhead  (5). 2. Position  pulley  (6)  forward  in  bracket  (2).   Wire rope  (1)  shall  be  forward  in  groove  (7)  of pulley. 3. Make  sure  two  washers  (8)  are  in  place  on  top and  bottom  of  pulley  (6). 14-39