TM 55-1520-240-23-10
13-8
INSTALL HEATER
(Continued)
13-8
25.
Remove caps from fuel tube (31) and elbow (32).
Acetone (E20) can form toxic vapors
if exposed to flame. Use acetone in
well-ventilated areas, away from heat
and open flames. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
26.
Clean shielded lead (33) with acetone (E20).
Connect shielded lead to spark igniter (34). Wear
gloves (E184.1).
27.
Remove plug and connect fuel tube (31) to elbow
(32).
FOLLOW-ON MAINTENANCE:
Check operation of heater (TM 55-1520-240-T).
Install acoustical blanket (Task 2-210).
END OF TASK
13-51