• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
REPLACE  LOCKED-IN  STUD (AVIM) (Continued) - TM-55-1520-240-23-1_50
REPLACE  SCREW-THREAD  INSERT (AVIM)

TM-55-1520-240-23-1 UH-1H/V and EH-1H Aircraft Manual
Page Navigation
  19    20    21    22    23  24  25    26    27    28    29  
TM  55-1520-240-23-1 1-15 REPLACE  LOCKED-IN  STUD (AVIM) (Continued) 1-15 18. Coat lock  ring  (4)  with  primer  (E292.1).   Wear gloves (E184.1). 19. Position  lock ring  (4)  over  stud  (2),  undercut  (9) toward  housing  (1).   Align  serrations (10)  with serrations  on  housing  and  flange  (6)  as  much as  possible. 20 Drive  lock  ring  (4)  around  flange  (6)  and  into housing  (1).  Use  special  drive  tool  (11). For Stud: Use Tool: MS51989-104 S91D-10 MS51989-105 S101D-12 MS51989-106 S111D-12 MS51989-107 S121D-12 MS51992B-504-13 SF5902-4D SHF101-9SA(8)A S101D-12 ST-10045 S101D-12 21. Remove  any  protective  covering  from  area  of stud  (2)  installation. INSPECT NO  BREAK  -  WORK  HARDER NO  BREAK  -  WORK  HARDER FOLLOW-ON  MAINTENANCE: None END  OF  TASK 1-26