TM 55-1520-240-23-1
1-15
REPLACE LOCKED-IN STUD (AVIM)
(Continued)
1-15
14.
Turn and remove stud (2) and remaining part
of lock ring (4) from housing (1). Use screw
extractor in pilot hole (7).
NOTE
As stud comes out, it will lift out
remaining lock ring. If it does not,
use punch to collapse and remove
remaining ring.
INSTALL STUD
When cleaning with compressed air,
debris thrown by pressure can injure
eyes. Do not use pressure over 30
psi. Wear eye protection.
15.
Clean any debris from hole (7) in housing (1).
Use low-pressure compressed air.
Stud can be damaged if not installed
to correct depth.
NOTE
Install same size stud as removed.
16.
Coat flange (6) and large thread of stud (2) with
primer (E292.1). Wear gloves (E184.1).
17.
Install stud (2). Use special wrench (8). Make
sure top of flange (6) is 0.010 to 0.020 inch
below surface of housing (1).
1-25