TM  55-1520-240-23-1 1-85 DUSTY  ENVIRONMENT MAINTENANCE 1-85 INITIAL  SETUP Applicable Configurations: All Tools: Brush Compressed  Air  Source Materials: Cloth  (E120) Solvent  (E161) Gloves  (E186) Personnel  Required: Medium  Helicopter Repairer Equipment  Conditions: Battery Disconnected  (Task  1-39) Electrical  Power Off Forward  Transmission  Fairing  Work Platforms  Open (Task  2-2) Aft  Pylon  Work  Platforms Open  (Task 2-2) Drive  Shaft Tunnel Access Covers Open  (Task 2-2) Aft  Landing  Gear Access Panels Open  (Task 2-2) General  Safety  Instructions: Dry  cleaning  solvent  (E161)  is combustible  and  toxic.   It  can  irritate skin  and  cause  burns.  Use  only  with adequate  ventilation,  away  from  open flame.  In  case  of  contact, immediately flush  skin  or  eyes  with  water  for at  least  15  minutes.   Get  medical attention  for  eyes. Do  not  use  more  than  30  psi compressed  air for cleaning  purposes. Debris  propelled  under pressure  can cause  injury  to  eyes.  Use  source  of compressed  air  under 30  psi  and eye  protection  to  prevent  injury  to personnel. NO  BREAK  -  WORK  HARDER 1-311