  229    230    231    232    233  234  235    236    237    238    239  
TM  55-1520-240-23-1 1-62 MANUAL  SERVICE  HYDRAULIC SYSTEM  RESERVOIR 1-62 INITIAL  SETUP Applicable  Configurations: All Tools: None Materials: Hydraulic  Fluid  (E199) Cloths  (E120) Personnel  Required: Medium  Helicopter Repairer References: TM  55-1520-240-T Equipment  Condition: Battery Connected  (Task  1-39) Electrical  Power  Off Hydraulic  Power Off Cargo  Ramp  Full  Up  or  Fully  Down  (TM 55-1520-240-T) NOTE This  procedure  applies  to  utility hydraulic  system  and  both  flight control  hydraulic  systems. 1. In  aft  cabin,  set  FLT  CONT  switch  (1)  on MAINTENANCE  PANEL  (2) to  No.  1. 2. Press and  hold  LEVEL  CHECK  button  (3).  Read No.  1  flight  control  system  reservoir  fluid  level on  gage  (4).   Read  utility  system  reservoir  fluid level  on  gage  (5). 3. Set switch  (1) to  No.  2.  Read  No.  2  flight control system  reservoir fluid  level  on  ramp-up  scale  of gage  (4). 4. Release  button  (3).   If  all  fluid  level  indications are  FULL, go  to  Follow-On  Maintenance. 1-240