TM 55-1520-240-23-1
1-36
APPLY POWER USING APU
(Continued)
1-36
SHUT DOWN APU
11.
Set PWR XFR NO. 1 and PWR XFR NO. 2
switches (9 and 10) to OFF.
12.
Set APU GEN switch (14) to OFF.
13.
Set APU switch (11) to OFF.
14.
Set BATT switch (6) to OFF.
NO BREAK - WORK HARDER
NO BREAK - WORK HARDER
FOLLOW-ON MAINTENANCE:
Disconnect battery (Task 1-39).
Install protective covers (Task 1-32).
END OF TASK